AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
218 Manual P/N 7003-961 Rev AA
Number Message String Cause Remedy
27 “Frequency error” Frequency is out of
allowable range.
Indicates a problem with
programmable controller.
28 “Phase error” Incorrect phase
29 “DC component
exceeds limit”
The waveform
selected contains a
DC offset that
exceeds the AC
mode capability.
Select AC+DC mode.
30 “Amplifier fault” Amplifier fault. Contact customer service.
31 “Warning negative
power near limit”
Approaching limit on
the amount of power
that can be fed back
into the supply by an
active load. This is a
warning only.
Stop increasing power feedback into
the power supply. Typically occurs
when using AC inverters. If power
increases further, an error 32 will be
generated.
32 “Negative power fault” Too much power fed
back. Power source
output disconnected.
Reduce the amount of power being
fed back into the power source.
Table 8-4 : Error Messages