8.1.2.1 Specific Test Limitations and Discrepancies
While every effort has been made to provide comprehensive coverage of the Airbus AMD tests, some
limitations apply, largely due to hardware limitations of the iX power source. The following table lists
specific implementation issues by test number. The deviation from the standard requirement is shown
in the “Actual setting” column. The reason for the deviation is shown in the last column.
8.1.3 Lx/Ls Series –AMD Option Limitations
The extent of coverage of the –AMD option as implemented on the Lx/Lx Series platform is shown in
the table below. Tests marked with an „x‟ generally require additional hardware to be used. Tests
marked „N/A‟ are not applicable to the corresponding table. Tests marked with a „‟ are covered by
the –AMD tests. Tests marked with a „P‟ require arbitrary waveform capability, which is available on
Lx models or Ls models with the –ADV option only. Additional implementation issues may apply as
well as indicated in section 8.1.3.1.