Ametek 2120 PLC Interface Module Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sensores Ametek 2120 PLC Interface Module. AMETEK 2120 PLC Interface Module User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 64
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
R
ESOLVER
& LDT I
NTERFACING
2120
PLC Interface Module
Series 956
ABSOLUTE PROCESS CONTROL
KNOW WHERE YOU ARE... REGARDLESS
INSTALLATION MANUAL
Series 2120
2120 Manual Z71.indd 12120 Manual Z71.indd 1 8/22/2005 8:32:38 AM8/22/2005 8:32:38 AM
Vista de página 0
1 2 3 4 5 6 ... 63 64

Resumo do Conteúdo

Página 1 - INSTALLATION MANUAL

RESOLVER & LDT INTERFACING2120 PLC Interface ModuleSeries 956ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESSINSTALLATION MANUALSeries

Página 2

6Installation and Programming ManualChapter 2: Hardware OverviewPOSITION This position LED turns on when the Interface Module is showing

Página 3 - Contents

Installation and Programming ManualChapter 3: Mounting and Wiring7This chapter provides instructions for mounting and wiring the PLC Interface Module

Página 4

8Installation and Programming ManualChapter 3: Mounting and Wiring5. Insert each #6-32 UNC screw into each of the module’s screw holes.6. Usi

Página 5

Installation and Programming ManualChapter 3: Mounting and Wiring9Figure 3-1 Dimensional DrawingDrawing E0232200AUX 3AUX 2AUX 1PROGRAM FLT OK MVT

Página 6

10Installation and Programming ManualChapter 3: Mounting and WiringThis section contains pinout diagrams for each module. System wiring diagrams fol

Página 7 - 2.1: Standard Modules

Installation and Programming ManualChapter 3: Mounting and Wiring11Figure 3-3 Relay Output Pinout DiagramFigure 3-4 Power Supply Pinout DiagramPowe

Página 8

12Installation and Programming ManualChapter 3: Mounting and WiringResolver Module (FMIR01)The resolver module has an eight-position connector. (See

Página 9 - 2.3: Status LEDs Defi ned

Installation and Programming ManualChapter 3: Mounting and Wiring13Figure 3-7 LDT Pinout Diagram Input Option L1LDT Input (FMIP02) Input Option L1Th

Página 10 - Chapter 2: Hardware Overview

14Installation and Programming ManualChapter 3: Mounting and WiringAnalog Output (FMOA01) Output Option A1The Analog Output board provides two channe

Página 11 - 3.1: Mounting

Installation and Programming ManualChapter 3: Mounting and Wiring15Figure 3-10 Resolver - Based System Wiring DiagramDrawing E0235800AUX 3 INPUT77L

Página 12 - Cabling

i Installation and Programming Manual1080 North Crooks RoadClawson, MI 48017-1097Phone: (248) 435-0700FAX: (248) 435-8120Internet: www.ametekapt.c

Página 13 - Drawing E0232200

16Installation and Programming ManualChapter 3: Mounting and Wiring L2100-240VAC 50/60HZPOWER SUPPLYPOWER1 L1PROBERELAY4 3 2 1C.P.U. FLT CHK AUX INPF

Página 14 - 3.2: Wiring

Installation and Programming ManualChapter 3: Mounting and Wiring17Figure 3-12 LDT - Based System w/Cable Termination Kit, Wiring DiagramDrawing E02

Página 15 - Power Supply Module (FMPS01)

18Installation and Programming ManualChapter 3: Mounting and WiringFigure 3-13A Digital Output Wiring DiagramDrawing E0232200DATA OUT BIT 19DATA OUT

Página 16 - Resolver Module (FMIR01)

Installation and Programming ManualChapter 3: Mounting and Wiring19Figure 3-13B Digital Output Wiring DiagramDrawing E0232200POWER SUPPLYCUSTOMER DC

Página 17

20Installation and Programming ManualChapter 3: Mounting and WiringFig 3-14 Wiring Diagram Analog OutputDrawing E8005090 L2100-240VAC 50/60HZPOWER

Página 18

Installation and Programming ManualChapter 4: Programming21This chapter provides detailed descriptions and instructions for programming all Interface

Página 19 - Drawing E0235800

22Installation and Programming ManualChapter 4: ProgrammingFigure 4-1 calls out the Interface Module’s programming keys. Following this fi gure are d

Página 20 - POWER 4 3 2 1

Installation and Programming ManualChapter 4: Programming23 The shift key is used to move to a specifi c digit show

Página 21 - Drawing E0228600

24Installation and Programming ManualChapter 4: ProgrammingTurns Counting Wrap Around (308)When using the Turns Counting software described above whe

Página 22

Installation and Programming ManualChapter 4: Programming25NOTE: The Interface Module is defaulted to stay in program mode for 120 seconds. The m

Página 23 - VOL = .44 MAX @IOL = 24mA

Installation and Programming Manual iiContentsChapter 1: Theory of Operation

Página 24 - Drawing E8005090

26Installation and Programming ManualChapter 4: ProgrammingProgram Position Offset (302)13. Select the function key. The monitor displays “F--

Página 25 - Chapter 4: Programming

Installation and Programming ManualChapter 4: Programming27There are two input cards available for use with LDTs. 1. Specifi ed as option V1 in the

Página 26

28Installation and Programming ManualChapter 4: ProgrammingWire Speed (300)Programming of the wire speed synchronizes the performance of the module w

Página 27 - Turns Counting (301)

Installation and Programming ManualChapter 4: Programming29Position Offset (302)NOTE: The display will read in inches or millimeters when used wit

Página 28 - Position Offset (302)

30Installation and Programming ManualChapter 4: Programming307NOTE: The Variable Pulse with external interrogation mode is not compatible with the

Página 29 - Enter 0 or 1

Installation and Programming ManualChapter 4: Programming31This section provides descriptions and instructions for the Interface Module setup functio

Página 30 - Enter desired

32Installation and Programming ManualChapter 4: ProgrammingEnter either 0, 1, 2, or 313Decimal Location (13)The Decimal Location function is used to

Página 31 - Position

(F)Installation and Programming ManualChapter 4: Programming33used for the Position Hold dwell time. The position hold dwell time is the amount of

Página 32 - Count Direction (301)

34Installation and Programming ManualChapter 4: Programming12Enter new time-out value The monitor displays “F-----”2. Select function number

Página 33

Installation and Programming ManualChapter 4: Programming35401To put the monitor in program mode, see Program Mode Access in Section 4.7: Program an

Página 34 - LDT Output Type (307)

iii Installation and Programming Manual4.2 : LDT Confi guration Functions...

Página 35 - 4.3: Monitor Setup Functions

36Installation and Programming ManualChapter 4: ProgrammingEnter 2110403Enter lower end limitEnter either0 or 1402 The monitor displays the func

Página 36 - Position Hold (15)

Installation and Programming ManualChapter 4: Programming37NOTE: After overriding either the upper or lower limit relays, the operator should move

Página 37 - Auxiliary LED (16)

38Installation and Programming ManualChapter 4: Programming3. Enter either 0 or 1. 0 = Latch (default) 1 = Synchronize Select

Página 38 - Move Detection Time-out (12)

Installation and Programming ManualChapter 4: Programming394.6: Analog OutputsThe Analog Output board provides two channels of analog output that ca

Página 39 - Lower End Limit (401)

40Installation and Programming ManualChapter 4: Programming B) Select voltage or current output 1. Select the function key. The monitor dis

Página 40 - Relay Override (403)

(F)Installation and Programming ManualChapter 4: Programming41 4. Enter function number X02. Select enter key. The monitor d

Página 41 - 4.5: Digital Outputs

42Installation and Programming ManualChapter 4: ProgrammingAnalog output channel 2 is programmed using the same basic sequences except with the funct

Página 42 - Logic Level (202)

Installation and Programming ManualChapter 4: Programming434.7: Program and Supervisory Mode FunctionsThis section provides descriptions and instruc

Página 43 - 4.6: Analog Outputs

44Installation and Programming ManualChapter 4: ProgrammingNOTE: If the Interface Module displays only one zero (i.e. “0”), then the program locko

Página 44

Installation and Programming ManualAppendix A: Error Messages45 The Interface Module displays an error message when an error occurs during machine op

Página 45

1 Installation and Programming ManualChapter 1: Theory of OperationThe Gemco Series 2120 PLC Interface Module converts the input signal from a resolve

Página 46

46Installation and Programming ManualAppendix A: Error MessagesLWR LIM UPR LIM MVT FLT FLT OKPROGRAM AUX 1 AUX 2 AUX 3 POS RPM Describes the T

Página 47 - Program Mode Access (10)

Installation and Programming ManualAppendix A: Error Messages47The following charts contain descriptions and solutions for the three types

Página 48 - Program Mode Time-Out (11)

48Installation and Programming ManualAppendix A: Error MessagesThe following chart contains errors that will cause the fault check relay to open:Char

Página 49 - Appendix A: Error Messages

Installation and Programming ManualAppendix A: Error Messages49The following errors will cause the upper and lower limit relays to de-energize:Chart

Página 50

(F)50Installation and Programming ManualAppendix A: Error MessagesError Conditions (306)If the monitor displays “SEr320” one of four error condition

Página 51

Installation and Programming ManualAppendix B: Function Summary51Appendix B: Function Summary ChartThis Appendix contains three function summary cha

Página 52 - Chart A-3 Entry Errors

52Installation and Programming ManualAppendix B: Function SummaryChart B-2 Resolver-Specifi c Function Summary Chart B-1 General FunctionThe followi

Página 53

Installation and Programming ManualAppendix C: Catalog Numbering Sequence53Figure C-1 Catalog numbering system2120 V1 K1

Página 54 - Error Conditions (306)

54Installation and Programming ManualAppendix D: Specifi cationsElectromagnetic Rating: IEC 801-2, Level 3

Página 55 - LDT based system

Installation and Programming ManualAppendix D: Specifi cations55RS-232 Output: Up to 115.2K baud, not less than ±5V in

Página 56 - Appendix B: Function Summary

2Installation and Programming ManualChapter 2: Hardware OverviewFigure 2-1 Interface Module with Resolver/Digital ModulesThis chapter contains descr

Página 57

56Installation and Programming ManualGlossaryGlossaryAccess Code This is a four-digit number that must be entered in the Pro

Página 58 - Appendix D: Specifi cations

Installation and Programming ManualGlossary57thus improving the resolution.Relay Output Module This module contains an upper and lower limit

Página 59 - = .44 max @ IOL = 24mA

58Installation and Programming ManualIndexIndexAAnalog Output 4Auxiliary LED Function 32, 50CCount Direction 27DDecimal Location Function 31, 50Digi

Página 60 - Glossary

Installation and Programming ManualIndex59SScale Factor (300) 22, 23, 51 TTurns Counting (301) 22, 23, 24UUnit of Measurement Function 29, 30,

Página 61

1080 N. Crooks Road, Clawson, MI 48017-1097 Phone: 248.435.0700 Toll Free: 800.635.0289 Fax: 248.435.8120 www.AMETEKAPT.com2120.M2R8/05.Z712CCopyright

Página 62

Installation and Programming ManualChapter 2: Hardware Overview32.2: Input/Output Modules2.1: Standard ModulesThis section provides descriptions of

Página 63

4Installation and Programming ManualChapter 2: Hardware OverviewVariable Pulse (FMIP01) Input Option V1 This module is used with an LDT that provide

Página 64 - 8/05.Z71

Installation and Programming ManualChapter 2: Hardware Overview52.3: Status LEDs Defi nedThe Interface Module has 10 status LEDs and four programming

Comentários a estes Manuais

Sem comentários