IEEE 488.2 and SCPI Command Operation Sorensen SF Series
3.7
3.7.1
3.7.2
OUTPUT SCPI Command Subsystem
OUTPUT SCPI Command Summary
OUTPut
:PROTection
:DELay <0+NRf>
:DELay?
:FOLD <0|1|2>
:FOLD?
:STATe <boolean>
:STATe?
:TRIPped?
OUTPUT SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.
Command Description SCPI Q?
OUTPut
Output subsystem. C
:PROTection
N
:DELay <0+NRf>
Sets the programmable time delay executed
by the supply before reporting output
protection conditions after a new output
current is specified.
N Q
:FOLD <0|1|2>
Sets the foldback (program down) mode of
the supply. Valid arguments are 0 (OFF or do
nothing, do not program down to zero), 1(Not
used), or 2 (program down to zero upon
entering constant-current mode).
N Q
:STATe <boolean>
Sets the output to zero or the programmed
value. Valid arguments are 1/ON or 0/OFF.
*RST state value is ON.
C Q
:TRIPped?
Returns the integer value 1 (TRIPPED) or 0
(UNTRIPPED) state of the output.
N
3-14 M550292-03 (Programming)