Installation and Maintenance Manual
Chapter 3: Programming
3.10: Clear an Existing Setpoint
A) Unit must be in the Program mode.
B) Depress .
C) Depress or key until setpoint to be cleared is on the display.
D) Depress the key. Upon depression of the key, the setpoint on
the display after Step C is deleted.
E) This keypad sequence must be completed once to clear an ON setpoint and a second time to
clear the OFF setpoint. See Section 3.9: Setpoints
CIR#
--
CIR ON
(Output to be Cleared) ENT
CIR OFF
CLR SETCLR SET
3.11: Clear All Setpoints
There are two methods of clearing all setpoints. This is accomplished as follows:
A) Unit must be in the Program mode.
B) To clear all of the setpoints in the active program, depress: .
The active program is the program currently selected using Code 771. See Section 3.7:
Setpoint Formula.
-OR-
C) To clear all the setpoints in all programs, depress: .
CIR#
-
9
-
1
ENT
ENT
CIR#
-
3
-
9
-
1
--
NOTE: CIR# 91 and CIR# 391 only clear out programmed setpoints. They do not clear out Linear
Speed ramps or change circuits that have been selected as Linear Speed; however, they will
clear the setpoints programmed in these circuits.
3.12: Setpoint Availability
Every 1995 PLS has a limit on the number of setpoints that can be stored in memory. On units with the
Multiprogram option, refer to Section 3.7: Setpoint Formula to calculate the maximum amount of
setpoints available.