AC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 107
Table 4-2. AC Faults and Enables Register 0
31-27 RESERVED
26 0x04000000 IOTP4 Impending Over Temperature – 4 Fault
25 0x02000000 IOPT3 Impending Over Temperature –3 Fault
24 0x01000000 OTP4 Over Temperature –4 Fault
23 0x00800000 OTP3 Over Temperature –3 Fault
22 0x00400000 BCKRI Back Plane remote inhibit
21 0x00200000 IOCP Inrush Over Current
20 0x00100000 DCUVP DC Bus Under Voltage Protection
19 0x00080000 DCOVP DC Bus Over Voltage Protection
18 0x00040000 SYNCF Synchronization Fault
17 0x00020000 DCP DC protection Fault
16 0x00010000 IIPK Inverter Peak Over Current
15 0x00008000 UVP12 Under Voltage Plus 12 Volt Fault
14 0x00004000 OVP5 Over Voltage Plus 5 Volt Fault
12 0x00001000 AFF Air Flow Fault
11 0x00000800 OTP2 Over Temperature –2 Fault
10 0x00000400 OTP1 Over Temperature –1 Fault
9 0x00000200 IOTP2 Impending Over Temperature –2 Fault
8 0x00000100 IOTP1 Impending Over Temperature –1 Fault
7 0x00000080 DES_MODE Desired Mode – CC/CV switch mode Fault
6 0x00000040 UVP Under Voltage Fault
5 0x00000020 ROVP Redundant Over Voltage Fault
4 0x00000010 ROCP Redundant Over Current Fault
1 0x00000002 ADC ADC Timing Fault
0 0x00000001 LDF Line Drop fault
Table 4-3. AC Faults and Enables Register 1
16-31 RESERVED
15 0x00008000 AUXF Auxiliary Relay Fault
14 0x00004000 ANALOG Analog Fault
13 0x00002000 RESERVED
12 0x00001000 RESERVED
11 0x00000800 MDENA Front Panel Module Enable False
10 0x00000400 GPRF Group Fault
9 0x00000200 PRST Power Reset
8 0x00000100 PRIENA Under/Over Voltage on PFC Bus
7-4 RESERVED
3 0x00000008 GNDF Ground Fault
2 0x00000004 OVM12 Over Voltage Minus 12 Volts Fault
1 0x00000002 UVM12 Under Voltage Minus 12 Volts Fault
0 0x00000001 OVP12 Over Voltage Plus12 Volts Fault