M380056-03 Rev M 89
4.
AC MODULE REMOTE PROGRAMMING
4.1
INTRODUCTION
The ReFlex Power™ AC power supply (ACPS) utilizes an Ethernet interface for
remote control of all programming, readback, and configuration setup. The
syntax of all SCPI commands implemented by the ReFlex Power™ system and
documented in this manual, are either SCPI confirmed in the SCPI 1999.0
Specification, Volume 2: Command Reference, or they are customized
commands not part of the SCPI definition but conform to SCPI syntax.
4.2
FEATURES AND FUNCTIONS
This section lists the features, programmable functions and readback functions of
the ReFlex Power™ ACPS.
F
EATURES
16-bit programming and 16-bit readback of voltage, and current, and
frequency (and phase, if in a phase group)
Programmable Over/Under Voltage protection with reset
SCPI compliant command set
User selectable Constant-Voltage/Constant-Current mode, with reset
Field-upgradeable firmware via Ethernet
Soft calibration
P
ROGRAMMABLE
F
UNCTIONS
Output voltage, current, and frequency (and phase if in a phase
group)
Soft limits for voltage and current
Over Voltage and Under Voltage protection
Programmable Over Current trip point, response time and delay time
Programmable Inrush Over Current trip point
Output enable/disable
Maskable fault interrupt
Full calibration
Programmable voltage range
Vista de página 92